Your current position:Home > Product > Change frequency power

Change frequency power

Publication time : 2018-6-25 14:50:59 
Change frequency power
The VFP frequency conversion power is the new generation 32 bit processor of ARM, which is used by Xun Chang company as the core. IGBT is the executive component, and the isolation transformer is designed for voltage conversion.


It uses the AC-DC-AC (AC - DC - AC) mode to convert the input power into any power supply in the world through the SPWM (sinusoidal pulse width modulation) transformation to meet the needs of different voltages and frequencies.
Product features

ARM-32 bit microprocessor control is reliable, stable and intelligent;
The dynamic response and the speed of stability are fast;
Three phase vector control, three-phase voltage automatic balance;
High precision;
The frequency is high;
7 Inch Touch screen display and control, beautiful interface, multi parameter display;
VF working curve, specially designed for motor test, has the function of soft start of inverter, and has pure sine wave of frequency conversion power supply;
RS232 communication interface, standard MODBUS-RTU protocol, optional TCP/IP interface, remote viewing and control through mobile phone APP.


Optional Features

The RS232 interface of programmable frequency conversion power supply has PC or PLC monitoring interface. It has a standard RS232 interface (which can be converted to RS485/CAN/RJ45) to meet the MODBUS-RTU protocol and facilitate remote monitoring. You can set the working group to store several groups of voltage, frequency, working time, etc.

The DC28V interface of military medium frequency power supply has DC28V DC input interface and control switch, and the DC28V power supply can be embedded inside the cabinet to form a whole, convenient, beautiful and reasonable.

Input harmonic current suppressor, 12 pulse wave rectifier, 18 pulse rectifier and 3-21 harmonic filter, reduce the input harmonic current of the frequency conversion power supply, improve the power factor, avoid the interference of the frequency conversion power supply to the other equipment in the network.

The protection grade of marine electric power supply, optional outdoor IP65 protection grade shell, direct outdoor use, is the marine power supply; also can choose the container type power supply room, the power supply in the container, the installation of the environment temperature control equipment, insulation layer and so on;

Wide range input function, optional voltage input range + 50%, frequency input 25Hz-100Hz, especially suitable for small or small hydro power generation occasions. The output can be stable frequency and steady pressure.

Input parameters

Name

Idex

Remarks


Rated voltage

Three phase 380V/400V (can be customized for any voltage)
Single phase 220V/230V (can be customized for any voltage)

Three phase three wire (L1, L2, L3) + ground wire (PE)
Single phase two line (L, N) + ground line (PE)

Input voltage range

±15%(other ranges can be customized)

 

Input frequency

40-70HZ

 


Output parameters

Name

Idex

Remarks

Modulation mode

IGBT/SPWM

 

Output voltage

Three phase 0-520V adjustable, single-phase 0-300V adjustable (customizable higher voltage)

 

Output voltage stability (average)

±1%(Customizable higher precision)

 

Reaction time

2mS(For input voltage)

 

Voltage waveform distortion THD

< 2%(Linear load)

 

Output frequency

41Hz-73Hz adjustable,50/60/400Hz fixed(optional100Hz/200Hz,5-1000Hz can be customized)

 

Frequency stability

< 0.1%

 

Phase shift

When the load is three phase equilibrium or no load, it is ≤±1°; the 100% three-phase imbalance is ≤±4°

 

Three phase imbalances

Automatic balance of three-phase voltage

 

isolation transformer

△/Y

 


Control parameters

Name

Idex

Remarks


Main control element

The main measurement and control chip is ARM32 bit processor, and the inverter is IGBT.

 

Carrier frequency

4K;8K;12K;16K optional

 

Control voltage and current acquisition mode

Value of validity

 

control mode

Voltage closed loop control or current closed loop control or VF curve control.

 

Interface

RS232,MODBUS-RTU protocal

optional TCP/IP,GPRS


Display parameters

Name

Idex

Remarks

Display medium

7 inch touch screen or 192*64(LCD)

 




Display rated parameters

Input three-phase voltage and frequency;
Output three phase line voltage and frequency;
The average value of output line voltage;
Output power factor;
Output three-phase current;
Output active power, apparent power

 


Display alarm content

Fuse break, high IGBT temperature, high transformer temperature, IGBT fault, overload, undervoltage and so on.

 

Rated parameter display precision

1.0 grade

 

Voltage parameter resolution

0.1V

Customizable higher resolution

Current parameter resolution

0.1A

Customizable higher resolution


Protection parameters

Name

Idex

Remarks



Type of protection

nput no fuse switch, output no fuse switch, electronic circuit fast detection over current, overvoltage, overload, high temperature, short circuit and automatic jump off protection and alarm

 

Protection mode

Cut off the output

 


Physical parameters

Name

Idex

Remarks

Cooling mode

Natural cooling or forced air cooling or water cooling

 

Protection grade

Indoor IP21; outdoor IP33 or higher level

 

Name composition



Three phase model specification

Model

Capactiy(kVA)

Output current (A)

Dimension
W×D×H(mm)

high voltage

low voltage

VFP13-003 /VFP33-003

3

4.2

8.4

350×650×670 
(with wheels)

VFP13-006 /VFP33-006

6

8.4

16.8

VFP13-010/VFP33-010

10

15

30

VFP13-015/VFP33-015

15

23

46

460×700×1170 
(with wheels)

VFP13-020 /VFP33-020

20

30

60

VFP33-030

30

45

90

VFP33-045

45

68

136

780×650×1450

VFP33-060

60

91

182

VFP33-075

75

114

228

950×700×1600

VFP33-090

90

137

274

VFP33-120

120

183

366

VFP33-150

150

228

456

1200×750×1800

VFP33-200

200

304

608

VFP33-250

250

380

760

1400×800×2000

VFP33-300

300

456

912

VFP33-350

350

532

1064

1500×1050×2200

VFP33-400

400

608

1216

VFP33-500

500

760

1520

2400×1200×2200

VFP33-600

600

912

1824

VFP33-800

800

1216

2432

1500×1050×2200两柜

VFP33-1000

1000

1520

3040

1500×1050×2200三柜

VFP33-1200

1200

1823

3646

Note:
1. 90kVA and below are equipped with high and low voltage switching switches, the high voltage and low voltage files over 90kVA are selected for order.
2. the current in the table is calculated on the line voltage 380V, the actual use should be based on the highest voltage of the selected equipment to calculate the current;
3. Parallel machine can be selected and output switch cabinet according to the needs.



Single phase model specification

Model

Capactiy(kVA)

Output current (A)

Dimension
W×D×H(mm)

high voltage

low voltage

VFP11--500W

0.5

4.2

2.1

425×436×173 
(rack mount)

VFP11-001

1

4.2

8.4

VFP11-002

2

8.5

17

350×650×670 
(with wheels)

VFP11-003

3

13

26

VFP11-005

5

21

42

VFP11-010 /VFP31-010

10

42

84

VFP11-015 /VFP31-015

15

63

126

460×700×1170 
(with wheels)

VFP11-020/VFP31-020

20

84

168

VFP11-030 /VFP31-030

30

126

252

VFP11-045 /VFP31-045

45

189

378

780×650×1450

VFP31-060

60

252

504

VFP31-075

75

315

630

950×700×1600

VFP31-090

90

378

756

VFP31-120

120

504

1008

1200×750×1800

VFP31-150

150

630

1260

VFP31-200

200

840

1680

1400×800×2000

VFP31-300

300

1350

2700

Note:
1. 90kVA and below are equipped with high and low voltage switching switches, the high voltage and low voltage files over 90kVA are selected for order.
2. The current in the table is calculated on the line voltage 220V, the actual use should be based on the highest voltage of the selected equipment to calculate the current;

Note: upgrading of products may lag behind, and the technical information is for reference only.

Test of export equipment; frequency conversion of imported equipment; stable frequency and steady pressure of ship; test of energy consumption environment in laboratory; place to change frequency, stable frequency and stable voltage, etc.


Copyright© XunChang All rights reserved. Without permission to copy the picture and content of this station for commercial use is not allowed, the website information is for